View the slide viewer

Have questions about this assay kit?

INDIGlo Luciferase Detection Reagent Kit

SIZE SKU PRICE
10 ml each of-2x concentrated indiglo ldr and dilution buffer—
25 ml each of-2x concentrated indiglo ldr and dilution buffer—
50 ml each of-2x concentrated indiglo ldr and dilution buffer—
SIZE SKU
10 ml each of-2x concentrated indiglo ldr and dilution buffer
25 ml each of-2x concentrated indiglo ldr and dilution buffer
50 ml each of-2x concentrated indiglo ldr and dilution buffer

Product Description and Product Data

INDIGlo Luciferase Detection Reagent from INDIGO Biosciences is a glow type luciferase detection reagent designed for the quantification of firefly and beetle luciferase expression in mammalian cells. The INDIGlo Luciferase Detection Reagent kit is formulated as a 2x-concentrated reagent which contains both the Luciferase Detection Reagent (LDR) and Dilution Buffer and can be used for both homogenous and non-homogenous assay applications. With a signal duration of greater than 2 hours and with a less than 10% fluctuation in signal, the highly sensitive and stable luminescence signal of INDIGlo is ideal for the cost-effective processing of cell culture plates ranging from 96 to 1536-well format.

Features

  • 2X Concentration

  • Signal Duration >2 Hours
  • Use for 96- to 1536-Well Formats

Product Specifications

SpeciesN/A
Kit Components
  • 2x-concentrated INDIGlo LDR
  • Dilution Buffer
Shelf Life6 months
Shipping RequirementsDry Ice
Storage temperature-20C

Data

INDIGlo LDR performance from both Homogenous and Non-Homogenous assays. Dose-response analyses of Human AhR (INDIGO #IB06001, 96-well assay) was performed using the reference agonist MeBIO. AhR reporter cells were plated across two white assay plates, MeBIO treatment media were added, and the assay plates incubated for 24 hr. Plates were then processed with luciferase detection reagents in either a.) a homogenous or b.) a non-homogenous assay format. Resulting assay metrics are also shown from using another extended-glo detection reagent (Vendor X).
INDIGlo LDR potency is stable following repeated freeze and thaw cycles. INDIGlo LDR was frozen at -20°C and thawed either 1, 2 or 3 times, then used to quantify luciferase activity from HEK-293:luc cells cultured in a white 96-well assay plate. No loss of reagent potency is observed between these conditions.

Target Background

INDIGlo Luciferase Detection Reagent from INDIGO Biosciences is a glow type luciferase detection reagent designed for the quantification of firefly and beetle luciferase expression in mammalian cells. The INDIGlo Luciferase Detection Reagent kit is formulated as a 2x-concentrated reagent which contains both the Luciferase Detection Reagent (LDR) and Dilution Buffer and can be used for both homogenous and non-homogenous assay applications. With a signal duration of greater than 2 hours and with a less than 10% fluctuation in signal, the highly sensitive and stable luminescence signal of INDIGlo is ideal for the cost-effective processing of cell culture plates ranging from 96 to 1536-well format.

Citations

Alfaxalone anaesthesia increases brain derived neurotrophic factor levels and preserves postoperative cognition by activating pregnane-X receptors: an in vitro study and a double blind randomised controlled trial
Serrao, Goodchild
BMC Anesthesiol (2022) 22 (1), 401 DOI: 10.1186/s12871-022-01940-x
Cited by 16
Snippet: Following incubation, the treatment media were discarded and 100 μL of luciferase detection reagent (Indigo Biosciences) was added to each well. … MethodsIn vitro assay platform The activation of h-PXR by allopregnanolone and alfaxalone was measured by Indigo Biosciences, Inc., using Human Pregnane X Receptor (h-PXR) Assay Kit (supplier: Indigo Biosciences, Inc., 3006 Research Drive, Suite A1, State College, PA 16801, USA;+ 1 (814) 234-1919). …
FigureFigureFigure
Human PXR Reporter Assay Kit INDIGlo Luciferase Detection Reagent Kit
Tenofovir-disoproxil-fumarate modulates lipid metabolism via hepatic CD36/PPAR-alpha activation in hepatitis B virus infection
Suzuki, Suda, Yamamoto et al
J Gastroenterol (2021) 56 (2), 168-180 DOI: 10.1007/s00535-020-01750-3
Cited by 65
Snippet: PPARγ/α/δ or PXR reporter assay system (Indigo Biosciences, PA, USA) according to the Luciferase activity was quantified using a luciferase detection reagent (Indigo Biosciences,
Human PPARγ Reporter Assay Kit Human PXR Reporter Assay Kit INDIGlo Luciferase Detection Reagent Kit
Alfaxalone activates Human Pregnane-X Receptors with greater efficacy than Allopregnanolone: an in-vitro study with implications for neuroprotection during anesthesia
Serrao, Goodchild
bioRxiv (2020)
Cited by 4
Snippet: Following the incubation period, the treatment media were discarded and 100 μL of luciferase detection reagent (Indigo Biosciences) was added to each well. The resulting
INDIGlo Luciferase Detection Reagent Kit
Showing 1-3 of 4 papers.
Powered by BizGenius

Also available as a service

Luciferase Detection Reagent

Have questions about this assay kit?